MediaVerse S3 / acoustics5 · Contractor Detail Drawing · Acoustic Design Basis

Sylomer SR28 Pad Layout Plans

Top-view pad grids for all rooms using 150 × 150 mm Sylomer pads at 400 mm centers. Every plan shows the 10 mm perimeter gap and any local keep-out zones that must remain isolated from the float floor build-up.

Pad Size
150 × 150 mm
Thickness
25 mm
Grid
400 mm centers
Load Rating
28 kN/m²

VO Live Layout

24 pads
Room (equiv.): 319 × 133 cm Pad count: 24 Sylomer area: 0.54 m² Perimeter gap: 10 mm [AC]

Control Room Layout

42 pads
Room (equiv.): 258 × 270 cm Pad count: 42 Sylomer area: 0.95 m² Perimeter gap: 10 mm [AC]

Video/Podcast Layout

120 pads
COL-W 479 × 413 cm room footprint · 19.78 m² Pad count 120 · Sylomer area 2.70 m² · COL-W wrap keep-out

Summary Table

RoomPad CountSylomer Area m²Load Check
VO Live240.54Pass
Control Room420.95Pass
Video/Podcast1202.70Pass (COL_W wrap keep-out TBC)
Total1864.19Order 205 pads incl. 10% waste buffer