Per-Room Fixture Schedule
| Room | Fixture | Wattage | Position | Circuit | Notes |
|---|---|---|---|---|---|
| VO Live B304 | 1× LED panel | 200W | 94cm from west wall / 149cm from north wall | AV-02 | Tunable white 2700–3500K |
| Control Room B311 | 1× LED panel | 40W | 98cm from north partition / 118cm from buffer spine | AV-01 | Tunable white 2700–3500K |
| Video/Podcast B312-1 | 1× LED panel | 200W | 113cm from buffer spine / 247cm from east wall | LX-1 | Tunable white 2700–3500K — production lighting NEVER on AV-03 (LX-1/LX-2 only) |
Global requirement: ALL fixtures must be tunable white 2700–3500K (B307 requirement). No exceptions.
Tally Light System
TALLY-01
Type
Sonifex SignalLED 'RECORDING' sign, red (BOQ OA-02)
Position
Above external door D5 (Control Room, outside face)
Switch
Momentary switch inside Control
TALLY-02
Type
Sonifex SignalLED 'RECORDING' sign, red (BOQ OA-01)
Position
Above entrance door D1 (Video/Podcast, outside face)
Switch
Momentary switch inside Video/Podcast
| Element | Detail |
|---|---|
| Control | Momentary switch inside Control drives TALLY-01 (above D5); momentary switch inside Video/Podcast drives TALLY-02 (above D1) — each sign is switched locally (BOQ OA-01/OA-02/OA-03) |
| Signal cable | Low-voltage wiring per sign with its matched Sonifex PSU (LD variant ships with PSU; LDD needs its own per datasheet — never a shared blanket supply) |
| Conduit | Separate conduit from audio and power cables |
Dimming & Control
| Parameter | Specification |
|---|---|
| Protocol | 0-10V or DALI |
| Range | All main panels dimmable 0–100% |
| E-Light units | On/off only (not dimmable) |
Cable Separation & Mounting Rules
| Rule | Specification |
|---|---|
| Fixture mounting | Surface mount or suspended — NO penetrations through acoustic ceiling [AC] |
| Lighting power conduit | Separate from audio signal conduit (300mm minimum) |
| Lighting cable type | Standard NMY or NYM — not required to be shielded |
| Shared conduit | DO NOT share conduit with audio signal cables |
| Tally cable | Separate conduit from both audio and power |
[AC] No ceiling penetrations for lighting fixtures. Surface mount or suspend from grid only. Penetrating the acoustic ceiling compromises the plenum barrier system.